What’s Wrong With My Heat Pump? A Symptom-by-Symptom Guide

5 min

Quick answer: Many heat pump “problems” are normal: light frost in cold weather, a cloud of steam during defrost, long run times on cold nights. Real trouble looks different: a solid block of ice, aux heat running all day, cool air for more than a few minutes, or an outdoor unit that won’t start. Match your symptom below.

In this guide
  1. How do you figure out what’s wrong with your heat pump?
  2. What winter heat pump symptoms are normal?
  3. What winter symptoms mean something is wrong?
  4. What symptoms show up any time of year?
  5. What should you do next?

How do you figure out what’s wrong with your heat pump?

Find your symptom below, read the likely causes, then do the safe checks. Each entry starts by saying whether it’s normal or worth a call. A heat pump heats and cools with the same outdoor unit, so some of its winter habits look strange if you grew up with a furnace.

Before anything else, check the basics: the thermostat mode and setting, the filter, and the breakers for both the indoor and outdoor units. Those three settle a surprising share of calls.

What winter heat pump symptoms are normal?

Light frost on the outdoor coil

Usually normal. When it’s in the 30s and damp, the outdoor coil gets colder than the air and moisture freezes on it. The heat pump runs a defrost cycle every so often to melt it off. A thin white coating that comes and goes is the system doing its job.

Steam or a cloud rising from the outdoor unit

Normal. During defrost the coil warms up quickly and the melting frost turns to vapor. It can look like the unit is smoking. If it smells like burning or you see flames, that’s different: turn the system off and call.

A whoosh, then silence, then the fan restarting

Normal. Going into and out of defrost, the reversing valve (the part that switches the unit between heating and cooling) shifts refrigerant flow and makes a loud whoosh. The outdoor fan usually stops during defrost and starts again after. The first time, it sounds like something broke. It didn’t.

Water around the outdoor unit in winter

Normal. That’s melted frost from defrost. It should drain away. If it pools and refreezes around the base on a hard freeze, keep the area clear so it can drain. Never chip ice off the coil; the fins bend and puncture easily.

Long run times on cold nights

Usually normal. Heat pumps deliver steadier, gentler heat than a gas furnace and run longer to do it.

On a night in the 20s, a heat pump may run almost nonstop. If the house holds temperature, it’s fine. Our Texas freeze guide explains what to expect in a real cold snap.

What winter symptoms mean something is wrong?

A solid block of ice on the outdoor unit

Not normal. Frost should clear in each defrost. If the coil turns into a solid block, or ice builds on the top and fan, defrost isn’t working.

Common causes are a failed defrost sensor or control board, low refrigerant, a stuck reversing valve or a failed outdoor fan motor, or water dripping onto the unit from a gutter. Turn the thermostat to emergency heat to protect the unit and call.

Cool air from the vents in heat mode

Sometimes normal. During defrost the air can feel cool for a few minutes, and heat pump air at 90-something degrees feels cooler than furnace air. Cool air for longer points to a thermostat set wrong, a reversing valve problem or low refrigerant. Our guide to a heat pump blowing cold air walks through each cause.

Aux heat showing all the time

Worth a look. Auxiliary heat means backup electric heat strips are helping. That’s expected in defrost and on very cold mornings.

If “AUX” shows most of the day in mild weather, the heat pump may not be carrying its load, or the thermostat is calling for backup too early. Your power bill will tell you. See aux heat vs. emergency heat.

Winter electric bills jumped

Worth a look. The usual culprit is heat strips doing the heat pump’s job. Low refrigerant, a dead outdoor unit or a big thermostat setback each morning can all cause it.

What symptoms show up any time of year?

The indoor fan runs but the outdoor unit doesn’t

Call for service. Check the outdoor breaker first. If it’s on and the unit is silent or just hums, a failed capacitor (the part that starts the motors), contactor (the power switch) or motor is common. Don’t keep resetting a breaker that trips.

It won’t switch between heating and cooling

Check the thermostat first. Make sure it’s set to HEAT or COOL, not a mode that doesn’t match, and that the setpoint is above or below room temperature. Some thermostats wait a few minutes before switching. If the unit runs but the air is wrong for the mode, the reversing valve or its control may be at fault.

Heat pump turning on and off every few minutes

Worth a look. Starting and stopping every few minutes, called short cycling, wears out parts and leaves the house uneven. Causes include an oversized unit, a thermostat in a bad spot, a dirty filter, or a refrigerant or safety switch problem.

Water leaking indoors

Call soon. In cooling season the indoor coil makes lots of water. A clogged drain line or cracked pan sends it into the ceiling. Our freezing and leaking guide covers the causes and the quick checks.

Grinding, screeching or banging

Turn it off and call. Metal-on-metal sounds usually mean a failing motor bearing, a fan blade hitting something, or a loose part. Running it can turn a small repair into a big one. Our HVAC noise guide helps you tell sounds apart.

A burning or electrical smell

Turn it off at the thermostat and call. The first heat of the season can smell dusty for a few minutes as heat strips burn off dust. A sharp electrical or plastic smell that doesn’t fade is not normal.

For any symptom marked call, Gold Eagle’s technicians diagnose and repair heat pumps across the Austin area; see our heat pump services.

What should you do next?

  • Check the thermostat mode, the filter and both breakers.
  • Clear leaves, ice and stored items from around the outdoor unit.
  • Switch to emergency heat if the outdoor unit is iced solid or making bad noises.
  • Write down what you saw and when, including the outdoor temperature. It helps the technician find the cause faster.
  • If it’s been more than a year, book a heat pump check before winter.

Related guides: Heat Pump vs. Gas Furnace vs. Dual Fuel in Central Texas, What’s Included in an HVAC Tune-Up? and 10 Signs Your HVAC System Needs Maintenance.


About Gold Eagle Services: This guide comes from the team at Gold Eagle Services, a family-run Austin HVAC, indoor air quality and mold remediation company founded in 2017. We’re licensed (TACLA119235 and RCO1783), insured and bonded, and we serve homes across the greater Austin area.

Need help with this in your home? Learn about our heat pump services, or call 512-489-4653 to schedule a visit.

Related Gold Eagle service: AC repair in Austin

Same-day service
BookTextCall 512-489-4653Call